Software Features: |
| |
Clock-time/ starting-time/
sampling time set |
| |
Measurement/ store/ logger
operation |
| |
PC mode, data logger works as AD (analog-digital)
card
|
| |
Scaling of the channels, that means
menu-guided allocation of the mV signals according to
physical measurement sizes
|
| |
calibration for selected
sensors |
Data read-out/ deletion/ display Creation of ASCII files
for further processing with standard software (e.g.
Excel)
|
| |
Online and offline graphics |
| |
Display of the real-time
measurement values
|
|
| |
Modes of Operation: |
The following operational modes are supported by the software:
Operational mode 1:
PC mode, meaning data is shown directly on the PC display
and stored on the PC's hard disc.
Operational mode 2:
Logger mode, meaning data is stored in the memory of the data
logger and can be read out with the PC.
|
| |
Specifica-
tions: |
Housings are available in stainless steel or titanium.
Housing diameter approx.: 140 mm
Housing length overall approx.: 300 mm
|
|
 |
CAPlog - the Data Logger
This deap sea data logger is a high definition 16-channel data logger,
which was developed primarily for the environmental monitoring area
and thanks to the flexible soft-ware and a comfortable graphic user
surface, it is also most appropriate for many other applications.
The CAPlog is available to a depth of 4.000 metres.
| Applications:
|
Oceanology
Environmental technology
Research and development
Process technology
Geotechnology
Waste Water + Water management
Process control
The use of the most modern subassemblies, hardware and soft-ware
technology determine the performance parameters of the data
logger.
|
| Technicals
Specifications: |
| |
Inputs: 16 differential |
| |
Input voltage range: 0
- 5 VDC |
| |
Resolution: 16 Bit
Self-calibrating feature with an internal reference
voltage source FLASH memory for program and data (Memory
size: 1 MB)
|
| |
8 digital exits |
| |
RS 232 interface |
| |
Real-time clock, battery
buffered (internal Li cells) |
| |
Switchable voltage
4x supply voltage; max. 1A current load (combined current) |
| |
Supply voltage: 7 VDC
14 VDC |
|
|
Current consumption:
|
Sleep mode: approx. 150 µA
Operating mode: approx. 50 mA
Temperature operating range: -40 ° C ... + 80°
C
|
| Software: |
For operation of the data logger, the CAPlog
16.1 user surface is offered, which can be installed in any
PC or notebook with a Pentium® Processor of min. 133 MHz
under Windows® 95/98 or Windows® NT. Operation of
the CAPlog can be carried out by mouse or keyboard.